BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//Sabre//Sabre VObject 4.5.3//EN
CALSCALE:GREGORIAN
BEGIN:VEVENT
UID:sabre-vobject-f6a27d36-63aa-48c6-8e66-4af48821d3e9
DTSTAMP:20260909T153713Z
SUMMARY:Preventative and Corrective Maintenance Advanced of Sunny Central/ 
 SCS
DTSTART:20261207T080000Z
DTEND:20261211T133000Z
LOCATION:Sonnenallee 1\, 34266 Niestetal
DESCRIPTION:Preventative and Corrective Maintenance Advanced Training for S
 MA Sunny Central 2200 - 4600 UP and Sunny Central Storage | 07.-11.DEC 202
 6Description:System solutions with SC/SCS inverters are used in storage po
 wer plants and PV plants worldwide. They ensure the stability of transmiss
 ion lines and reduce energy costs through the use of photovoltaic energy. 
 In order to ensure the maximum efficiency and reliability of your inverter
  it needs to be maintained on a regular basis. This training empowers you 
 to autonomously conduct this maintenance work in accordance with the SMA m
 aintenance protocol\, as well as effectively localize causes for loss of p
 roduction and downtime. Furthermore\, this training enables you to autonom
 ously replace wear and tear parts preventatively and correctively in accor
 dance with the SMA maintenance protocol. That way a maximum of uptime and 
 yield of your inverter will be ensured.Target group:SMA customers with ele
 ctrical knowledgeMandatory Prerequisites:Employee of an existing SMA custo
 mer working with SMA inverters on-site (serial-no. of inverter has to be s
 tated during the booking process)Self-declaration stating that the partici
 pants of the course are qualified electricians\, who are aware of the pote
 ntial risks associated with electricity (as part of the online registratio
 n process)Participants must wear safety shoes and flame-resistant clothing
 Contents:Review of Electrical Safety to safely approach the inverter and m
 inimize the risk of exposure to electric shock and arc flashLive-demonstra
 tion on inverter components and functionality of DC\, AC Auxiliary Power\,
  Cooling\, Communication\, Data Logging and MonitoringExercises on real in
 verter how to perform preventive maintenance to maximize the system uptime
  and retain the SMA warrantyLearn and practice how to read circuit diagram
 s\, finding components and part numbersHands-on exercises on identifying f
 aults caused by the grid\, PV array/ battery or inverter componentsPractic
 e how to evaluate event and error codes in order to find the best solution
 Extensive hands-on exercises on component replacementComponent Replacement
  ListAfter this training you* will be able and qualified to:• Conduct pr
 eventative maintenance work in accordance with the SMA maintenance protoco
 l (relevant for retaining SMA warranty)• Effectively localize causes for
  loss of production and downtime\, as well as find solutions to remedy the
 se causes either on your own or with the help of SMA• Maximize your effi
 ciency in communicating with the SMA Service line and therefore help poten
 tial issues being solved faster• Conduct advanced corrective and prevent
 ative component replacement yourself (as stated in your service contract) 
 on components like power stacks\, interior fans\, GFDI breaker or 24Vdc po
 wer supply*please note that the certificate documenting your qualification
  is both bound to the attendee and the company the attendee is working for
  during the time of enrolling for the training course (i.e. the certificat
 ion is nullified if the attendee changes the company afterwards). The cert
 ificate is valid for 5 years after completion of the training and then mus
 t be renewed via an online refresher training.After this training you will
  not be qualified to:• Conduct maintenance work on any other inverter ty
 pe than the model line covered in your training• Train other employees o
 f your company on corrective and preventative maintenance of SC/SCS invert
 ers• Commission SMA inverters on your own (this service is offered by SM
 A specialists only)Component replacement list:· aux. Power fuses· aux. P
 ower switch· aux. Power overvoltage contactor· 24 Vdc power supply/ buff
 er module· 24 Vdc distribution fuses· Surge protection devices· LCD TFT
  display· precharge contactor· precharge fuses· GFDI breaker and aux. C
 ontact· remote GFDI motor· DCC / bender fuses· DCM electronic boards*·
  COM board*· RIO electronic board*· DCC electronic board*· ACC electron
 ic board*· DST electronic board*· air circulation / interior fans· lith
 ium-ion rechargeable battery (on COM board)· Industrial Compact Flash car
 d (on COM board)· AUX transformer· AC breaker complete· DC breaker comp
 lete· DC breaker components· Sine filter (choke and capacitors)· Stack 
 (three-phase power unit)*Please note: During the replacement process remot
 e connection to electronic boards must be available for SMA Service.Langua
 ge:English language
URL;VALUE=URI:https://www.eventbrite.de/e/preventative-and-corrective-maint
 enance-advanced-of-sunny-central-scs-tickets-1985356911968
END:VEVENT
END:VCALENDAR